Products

Tessiq

Dashboards for each building: current readings, history, equipment and open alarms on one page, built by your own team. Nobody has to sit and watch it. When an alarm or a report sends someone to look, Tessiq is where they land.

Dashboards

Where people land when something sends them to look.

A building’s dashboards are pages of what its team needs to see, drawn from the building’s own points. Follow a link from an alarm email or a report and the equipment, its readings and the open alarms are on one page.

  • Cards for the readings that matter, with their units
  • Charts of history, from the last half hour to the last thirty days
  • Run-status timelines, and a summary that says in a sentence what the equipment is doing
  • Equipment cards with Detect’s findings for each unit
  • The building’s open alarms from Tocsia
  • Notes and links for whoever opens the page
Tessiq · Tower A · OperationsExample
Data as of 8:21 AM · Last 24 hours
84.2 °FOutside air
44.1 °FChilled water supply
141.2 °FHot water supply
612 kWMain meter demandNot current: 42 min old

Chilled water supply

424446488 AM2 PM8 PM2 AM8 AM

AHU-41 · Detect

  • Critical Supply fan: commanded on, not proven.
  • Warning Discharge air: 6 °F above setpoint for 2 h.

Open alarms in Tocsia

  • In alarm AHU-41 Return CO2
  • Acknowledged VAV-3-07 Zone temperature
Tessiq · Tower A · PlantExample
612 kWMain meter demandNot currentLast reading 7:58 AM, more than 20 minutes ago.
No readingCondenser water supplyNot availableRequested; the site has not picked up the change yet.
0 gal/minChilled water flowKnown unreliableStuck at 0.

Known data issues

MeasurementProblemOperational impact
Chilled water flowKnown unreliableStuck at 0 gal/min while the chilled water pumps run.Plant load and ton-hours cannot be calculated.

Readings and history

Current readings, and nothing made up.

Readings come from the building about a minute behind, and history covers the last half hour up to the last thirty days. When a reading is late, missing or doubtful, the page says so instead of filling the gap.

  • Late. A reading more than twenty minutes old is marked not current, with the time of the last one, and a building that has stopped reporting is marked offline.
  • Missing. A point with no value says so, and why when it is known, instead of showing a blank or a zero.
  • Questionable. A sensor your team has marked as unreliable carries that mark beside every reading, and a list of known data issues says what each one affects.

Equipment and alarms

Detect’s findings and Tocsia’s alarms, beside the readings.

The equipment view sorts each building’s equipment by what needs attention, as Detect last judged it. Open a unit and each finding keeps Detect’s conclusion and its explanation apart, beside the values it read and the unit’s open alarms from Tocsia.

  • Needs attention, watch, no findings, and anything not current
  • Findings that are not current say so, with when Detect last judged them
  • An alarm panel on any page lists the building’s open alarms, each linked to its page in Tocsia
Tessiq · Equipment · AHU-41Example
Needs attentionTower A · Level 4 · evaluated 8:19 AM (2 min ago)

Current findings

Supply fanDetect’s conclusion: Critical, since 6:05 AMDetect’s explanation: Commanded on for 2 h 14 min, but the fan is not proven.
VentilationDetect’s conclusion: Warning, since 6:20 AMDetect’s explanation: Return air CO2 is 1,020 ppm, above the 1,000 ppm limit.

Measured

As Detect read them at 8:19 AM, its last evaluation; not live values.

Related alarms · Tocsia

Active AHU-41 return air CO2 high

alert · raised 6:12 AM

Tessiq · Editing OperationsExample

Pages

  • Overview
  • Air handlers
  • Plant

On this page

  • Outside air KPI Card
  • Chilled water supply KPI Card
  • Chilled water, last 24 hours Time Series
  • Open alarms Auto Alarm Panel

KPI Card

Title
Chilled water supply
Subtitle
Leaving the plant
Equipment
Chiller plant
Query mode
Direct Path
Point
Plant / CHW supply temp

Built by your team

Your managers build the pages.

A building’s managers build and change its dashboards in a visual editor: pages and sections in an outline, the page drawn on the building’s data as they work, every item edited in place, with undo and redo.

  • Point fields browse the points the building sends
  • Changes are saved as a draft, and everyone else keeps seeing the published dashboard until they are published
  • Everyone else sees the dashboards as published, chooses the time range, and can download data as a CSV file

Every building, one sign-in

Start from a layout, for any building you can see.

A new dashboard starts from an executive, operations or engineering layout, or a blank page, and can stay a draft until it is ready. A building switcher lists the buildings you have been given, with their status. One sign-in covers Tessiq and Tocsia, and Tessiq is turned on building by building.

Tessiq sends no alerts and asks nobody to watch it. Tocsia’s emails and Insight’s reports reach people; Tessiq is where they lead.

Tessiq · New workspaceExample

Pick a building and a starting point. You can change everything afterwards.

BuildingTower A
Start from
  • ExecutiveComfort, energy and equipment health at a glance, for owners and managers.
  • OperationsWhat needs attention now, and how the building got here, for the operations team.
  • EngineeringEquipment details, point trends and diagnostics, for engineers and technicians.
  • BlankOne empty page, to build up in the editor.
Start as a draftBuild it first: a draft asks the building for no points until you publish it.

One set of checks, four ways to act on them

Detect finds it. Tocsia flags it. Tessiq shows it. Insight explains it.

  • Detect

    Is each piece of equipment doing what it should?

  • Tocsia

    What needs attention now, and where do I start?

  • Tessiq

    What is the building doing now, and what has it been doing?

  • Insight

    What happened, why, and what should we do about it?

What would Smart Tenants find in your building?

Tell us about your building systems and we will show you what a morning briefing would say.