Products

Software that reads your building.

Every Smart Tenants product works from the systems your building already has and turns what it reads into something your team can act on.

Detect finds it. Tocsia flags it. Tessiq shows it. Mentiq explains it.

For facility teams, engineers and owners

Mentiq

Reports your team can act on, written from the data your building already produces: ready-made reports for every shift, custom reports for your own questions, and an executive view for owners.

Explore Mentiq
Mentiq · Site healthExample
9 of 9Devices online
2Open alarms
GoodCommunication quality
41Open conditions

Equipment health scores

  • AHU-1234No air while occupied
  • AHU-3852Fan alarm latched
  • Chiller 171Compressor hunting
  • AHU-0796Operating normally

For engineers and facility teams

Detect

Fault detection and diagnostics for HVAC, central plant, domestic hot water and meters, running on site around the clock. Every unit is checked continuously against what it should be doing, and each fault is named with its likely cause.

Explore Detect
Detect · AHU-38 · Fault Detection & DiagnosticsExample
Hide unavailable (2)
DiagnosticStatusDetails
Discharge airWarning8 °F above setpoint for 1 d 6 h. Cooling valve fully open: out of capacity, not out of control.
Duct staticWarning0.31 in. wc below setpoint. Fan near full speed: no headroom left.
Mixed airUnreliableSensor reads 212 °F, outside its physical range. Named, and left out of every check that uses it.
FilterInfoPressure drop 1.1 in. wc: schedule a change.
EconomizerInfoUnavailable: needs an outside air temperature, which this unit does not have.
Supply fanOKProven, near full speed.
CoilsOKNo heating and cooling at the same time.
CO2OKReturn air 640 ppm.
SafetiesOKFreeze stat, smoke detector and high-static switch normal.

For facility teams and engineers

Tocsia

Every building’s alarms in one place. Each alarm opens with what the equipment read when it raised, what Detect found on that unit, and suggested checks for where to start. Acknowledge it in Tocsia and the building’s server has it within seconds.

Explore Tocsia
Tocsia · Alarms · All buildingsExample
2Open nowstill in alarm
4Raised in the last 24 hoursabout 5 a day
1Points alarming every dayof 9 points
14 minTypical time in alarmmedian
PointStateWhat happened
AHU-41 Return CO2Tower A · raised 6:12 AM · in alarm 2 h 9 minIn alarmHigh: 1,020 ppm, limit 1,000
Chiller 1 Leaving waterCentral plant · raised 7:55 AM · in alarm 26 minIn alarmHigh: 48.6 °F, limit 46.0 °F
VAV-3-07 Zone temperatureTower B · raised 5:40 AM · in alarm 2 h 41 minAcknowledgedHigh: 79.4 °F, limit 78.0 °F
Boiler 2 Supply waterCentral plant · raised 4:18 AM · in alarm 35 minClearedLow: 138 °F, limit 140 °F

Repeats of one alarm fold into one line per point. A point that alarms every day is counted, and can be set aside so it does not bury a new one.

For facility teams, engineers and owners

Tessiq

Dashboards for each building: current readings, history, equipment and open alarms on one page, built by your own team. Nobody has to sit and watch it. When an alarm or a report sends someone to look, Tessiq is where they land.

Explore Tessiq
Tessiq · Tower A · OperationsExample
Data as of 8:21 AM · Last 24 hours
84.2 °FOutside air
44.1 °FChilled water supply
141.2 °FHot water supply
612 kWMain meter demandNot current: 42 min old

Chilled water supply

424446488 AM2 PM8 PM2 AM8 AM

AHU-41 · Detect

  • Critical Supply fan: commanded on, not proven.
  • Warning Discharge air: 6 °F above setpoint for 2 h.

Open alarms in Tocsia

  • In alarm AHU-41 Return CO2
  • Acknowledged VAV-3-07 Zone temperature

What would Smart Tenants find in your building?

Tell us about your building systems and we will show you what a morning briefing would say.