Fault detection and diagnostics for HVAC, central plant, domestic hot water and meters, running on site around the clock. Every unit is checked continuously against what it should be doing, and each fault is named with its likely cause.

Inside a unit

Every check, with its reasoning.

Open any unit to see each diagnostic, its status and what it found. Discharge air off setpoint is told apart: out of capacity with the valve wide open, out of control with room to spare, or the other coil fighting it.

A sensor that is offline or reads an impossible value is named and set aside, so one bad reading never turns into a false fault. A check that needs a sensor the unit does not have says so, and can be hidden.

Detect · AHU-38 · Fault Detection & DiagnosticsExample
Hide unavailable (2)
DiagnosticStatusDetails
Discharge airWarning8 °F above setpoint for 1 d 6 h. Cooling valve fully open: out of capacity, not out of control.
Duct staticWarning0.31 in. wc below setpoint. Fan near full speed: no headroom left.
Mixed airUnreliableSensor reads 212 °F, outside its physical range. Named, and left out of every check that uses it.
FilterInfoPressure drop 1.1 in. wc: schedule a change.
EconomizerInfoUnavailable: needs an outside air temperature, which this unit does not have.
Supply fanOKProven, near full speed.
CoilsOKNo heating and cooling at the same time.
CO2OKReturn air 640 ppm.
SafetiesOKFreeze stat, smoke detector and high-static switch normal.

What it checks

Checked the way an engineer walks the unit.

Detect works from the points your building automation system already has: commands, status, setpoints, temperatures, pressures, valve positions and meter readings. Each of the twelve kinds of equipment below has its own set of checks, and each check names the likely cause instead of just raising a flag. A few of each:

Air handlers

Including packaged rooftop units, dedicated outdoor air units and energy recovery units

  • Discharge air off setpoint or hunting around it, with the likely cause: out of capacity, out of control, or the other coil fighting it
  • Economizers taking warm air or missing free cooling, and damper linkage faults worked out from the temperatures
  • Fans commanded on but not proven, or left running in hand when commanded off

and more

VAV boxes

With or without reheat, and with series or parallel box fans

  • Zones outside their comfort band, and for how long
  • Dampers wide open but short of airflow, or hunting back and forth
  • Reheat open with no temperature rise

and more

Fan coils

Two- and four-pipe fan coils, unit ventilators, cabinet and unit heaters, blower coils

  • Spaces too warm or too cold while occupied, and whether the unit is at full output or not trying
  • A coil that does not change the air when its valve opens
  • Heating and cooling at once, and a two-pipe changeover that disagrees with the water

and more

Zone heat pumps

Water-source, ground-source and air-source units, packaged terminal heat pumps and VRF indoor units

  • A compressor running without heating or cooling the air enough
  • A reversing valve stuck: cooling when heat is called, or the reverse
  • Auxiliary heat on with the compressor off, or in mild weather

and more

Fans

Exhaust fans, from restrooms and kitchen hoods to garages, labs and machine rooms, and fans outside an air handler

  • Failing to start, running commanded off, or a status the speed or current contradicts
  • Broken or slipping belts, worked out from the motor current
  • Running without its partner, such as hood exhaust without make-up air

and more

Chillers

Each chiller on its own, with its compressor, refrigerant and water sides

  • Evaporator and condenser approach and temperature difference
  • High condenser pressure, low evaporator pressure and freeze risk
  • Reading as running when it is not, or running without cooling

and more

Chilled water plant

The loop, its pumps, the cooling towers and the isolation valves between chillers

  • Water passing through a chiller that is off while another runs
  • Supply warmer than the running chillers make it, and whether another chiller would help
  • A low loop temperature difference, and supply and return sensors that read backwards

and more

Boilers

Hot water boilers, condensing and non-condensing

  • Lockout, low water cutoff and high limit trips, with the alarm code
  • Firing with no water moving, not firing when called, or firing with no rise
  • Return water wrong for a condensing or non-condensing boiler

and more

Hot water plant

The heating loop, its pumps and the isolation valves between boilers

  • Supply colder than the running boilers make it, or below setpoint
  • A setpoint not following the outdoor reset
  • The plant left on in warm weather with no heating demand

and more

Pumps

Pumps outside a plant: secondary and zone loops, booster sets, sump and condensate pumps

  • A duty pump down with no standby taking over
  • Loop pressure short at full speed, or high at minimum
  • Pumps not taking turns, or more running than needed

and more

Domestic hot water

Water heaters, the storage tank, the mixing valve and the recirculation loop

  • Mixed water hot enough to scald, too cool, or off setpoint, telling the tank from the valve
  • Storage held below the minimum set for the building
  • Recirculation return running cool, with why

and more

Meters

Electric, gas, water and thermal meters

  • Water that never stops flowing, such as a leak or a running toilet
  • A new monthly peak demand, and high baseload after hours
  • Totals that stop counting, run backwards or jump, and gaps in history

and more

A check runs only when the points it needs are linked, so each unit is judged on the instruments it actually has.

Score and history

A running score, and the slide behind it.

Every unit carries a score from 0 to 100 that its own checks set. A critical finding takes more off than a warning, and a sensor that is offline or reads an impossible value costs points too. A check with nothing linked costs nothing, and how much each check matters can be tuned.

The score is recorded every hour beside the readings the checks use, so the history shows when a unit started to slide, what its fan and valves were doing at the time, and whether a repair brought it back.

Detect · AHU-38 · HistoryExample
Business hoursDual axis
  • Discharge air (°F)
  • Setpoint (°F)
  • Equipment score
506070050100MonTueWedThuFriSatSun

Tuned per unit

Fitted to the building, not a textbook.

  • Every limit can be set unit by unit: how far from setpoint, for how long, and at what level.
  • Each condition keeps the time it started through a short restart, and one bad reading never resets the clock.
  • Every unit keeps a record of how long it spent at OK, warning and critical, and how often it changed.
Detect · AHU-38 · PropertiesExample
SettingValueEdit
Fan proof delay60 sEdit
Discharge air warning band±7 °FTuned. Default ±5 °FEdit
Discharge air warning after15 minEdit
Discharge air critical band±10 °FEdit
Duct static warning band0.25 in. wcEdit
Duct static warning after20 minTuned. Default 10 minEdit
Filter change at1.0 in. wcEdit
Return CO2 warning1,000 ppmEdit

In your building system

Where your operators already look.

Each unit’s status is published on your network as a BACnet point: OK, warning or critical. The building automation system your team already uses can put it on its graphics and alarm on it, so a fault Detect finds reaches the operator’s screen with nothing new to log into.

Building automation system · PointsExample
PointValueUpdated
AHU-12 Detect statusCRITICAL2 s ago
AHU-38 Detect statusWARNING2 s ago
AHU-07 Detect statusOK3 s ago
VAV-2-14 Detect statusWARNING2 s ago
Chiller 1 Detect statusOK4 s ago

The operators’ own graphics and alarms read these points. Nothing new to log into.

Where findings go

To the people and systems that act on them.

  • On screen. Every unit’s diagnostics, live, on the server in your building.
  • In your building system. A status point per unit, for its graphics and alarms.
  • By email, Slack, Teams or PagerDuty. Alarms you set on any point, for a value out of range or a status that changes, go to the people who need them. Rules filter by severity, equipment and location, and batch messages so nobody is flooded.
  • On Tocsia’s alarm pages. When a point on the unit alarms, the alarm’s page shows what Detect found there at that moment.
  • On Tessiq’s dashboards. An equipment card shows the unit’s findings beside its readings.
  • Into Mentiq. With Mentiq, the findings feed the morning briefing and the equipment reports, ranked and explained.

Runs on site

Beside the system you already have.

Detect runs on a small server in your building, next to your building automation system, and reads it over BACnet. Detection keeps running if the internet connection drops. Nothing is ripped out or replaced.

One set of checks, four ways to act on them

Detect finds it. Tocsia flags it. Tessiq shows it. Mentiq explains it.

  • Detect

    Is each piece of equipment doing what it should?

  • Tocsia

    What needs attention now, and where do I start?

  • Tessiq

    What is the building doing now, and what has it been doing?

  • Mentiq

    What happened, why, and what should we do about it?

What would Smart Tenants find in your building?

Tell us about your building systems and we will show you what a morning briefing would say.